Subdivision

Concept Plan

3-SG-03-C

Recommended for approval
by the Planning Commission

APPROVE variance because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 10 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Walnoaks - Unit 7
Lots
27 (Split)

Variances

1. Intersection grade variance on Road B at Pinex Ln., from 1% to 2%.


Property Information

+
Location
East side and northeast end of Pinex Ln., northeast of Walpine Ln.

Council District 3


Size
9.50 acres

Sector
Northwest City

Currently on the Property
Vacant land

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variance because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 10 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (City Ord. 0-280-90).
3. Compaction of fill areas to be done in accordance with the requirements of the Knoxville Department of Engineering.
4. Meeting all applicable requirements of the Knoxville Department of Engineering.
5. Prior to final plat approval, the minimum lot size of 6000 square feet outside of the floodway area for each lot shall be verified using the surveyed subdivision boundaries and floodway boundary.
6. Place a note on the final plat that vehicular access to Lot 30 is to be from the internal street system only.
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
8. Revise the concept plan to include a sidewalk on one side of Pinex Ln. in compliance with the standards of the Knoxville Department of Engineering.
9. Meeting all requirements of the approved Use-on-Review development plan (6-L-96-UR).
10. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variance because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 10 conditions

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process