Subdivision

Concept Plan

7-SH-04-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 7 conditions:


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a 75' pavement radius in the cul de sac at the end of Peony Dr.
3. Provision of a typical local road cross section that shows compliance with Knox County's current standards.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the lake, common area, and drainage system.
6. Meeting all requirements of the approved use on review development plan.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Victoria's Landing
Lots
21 (Split)
Proposed Density
2.77 du/ac

Variances

1. Horizontal curve variance from 250' to 100' at sta 4+00 of Peony Dr.
2. Variance of right-of-way transition radius in a cul de sac from 75' to 25' on Peony Dr.
3. Variance to permit a hammer-head turn around at the end of Silveredge Rd. in lieu of a cul de sac.


Property Information

+
Location
South side of Silveredge Rd., south of E. Emory Rd.

Commission District 8


Size
6.47 acres

Sector
Northeast County

Currently on the Property
Single-family residence and vacant land.

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.


APPROVE the Concept Plan subject to 7 conditions:

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a 75' pavement radius in the cul de sac at the end of Peony Dr.
3. Provision of a typical local road cross section that shows compliance with Knox County's current standards.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the lake, common area, and drainage system.
6. Meeting all requirements of the approved use on review development plan.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 - 3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 7 conditions:

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a 75' pavement radius in the cul de sac at the end of Peony Dr.
3. Provision of a typical local road cross section that shows compliance with Knox County's current standards.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the lake, common area, and drainage system.
6. Meeting all requirements of the approved use on review development plan.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Victoria's Landing

Valley Group c/o Betty Rule


Case History