Planned Development
12-A-25-PD
To be heard December 11, 2025Agenda Item No. 19
Planning Staff Recommendation
Approve the final plan for a 3-story, 20,000 sqft eating and drinking establishment because it is in substantial compliance with the approved preliminary plan for the multi-use stadium/mixed-use planned development (9-A-21-PD), subject to 7 conditions.
Recommend that the City Council amend the zoning map to add the PD (Planned Development) designation to the subject property.
See case notes below
Request
Property Info
Case Notes
What's next?
Applicant Request
− +Zoning
- Current
I-MU, HP
I-MU (Industrial Mixed-Use), HP (Hillside Protection Overlay)The I-MU Industrial Mixed-Use Zoning District is intended to provide for a mix of light industrial uses and a variety of compatible commercial uses such as entertainment, amusement and retail establishments. This mix is designed to promote the reuse of older, character giving structures that may no longer be suitable for their original industrial purposes, but that can accommodate a variety of alternative types of uses. Residential uses are also permitted in the I-MU District, both above the ground floor in mixed-use development, and in multi-family dwellings.
The HP District is intended to protect Knoxville's significant natural topographic features, and to prevent potential serious consequences from hillside development, such as increased erosion, fire, or flood hazards, and property damage.
Land Use
- Current
Agriculture/Forestry/Vacant Land
ProposedFinal plan for a restaurant in the boundary of the multi-use stadium/mixed use planned development (9-A-21-PD)
Property Information
− +406 WILLOW AVE
Southwest side of Willow Ave, east of Hall of Fame Dr
Council District 6
Size
0.55 acres
Planning Sector
Central City
Land Use Classification MU-SD / MU-CC3 (Mixed Use-Special District, SOMAG), HP (Hillside Ridgetop Protection) MU-SD / MU-CC3 (Mixed Use-Special District, SOMAG), HP (Hillside Ridgetop Protection)
Agriculture/Forestry/Vacant Land
Growth Plan
N/A (Within City Limits)
Fire Department / District
Knoxville Fire Department
- Utilities
- Sewer
Knoxville Utilities Board
WaterKnoxville Utilities Board
Case Notes
− +Staff Recommendation
Approve the final plan for a 3-story, 20,000 sqft eating and drinking establishment because it is in substantial compliance with the approved preliminary plan for the multi-use stadium/mixed-use planned development (9-A-21-PD), subject to 7 conditions.Recommend that the City Council amend the zoning map to add the PD (Planned Development) designation to the subject property.
1. Modifications to the final plan must be approved in accordance with Article 16.7.F (Modifications to Approved Final Plans).
2. Approval of the zoning map amendment by City Council to add the PD (Planned Development) designation for the subject property.
3. The development shall be compliant with the City of Knoxville Zoning Ordinance unless an exception has been approved through the planned development process outlined in Article 16.7.
4. Meeting all applicable requirements of the City of Knoxville Engineering Department.
5. Installation of all sidewalks and walkways as identified on the site plan.
6. The landscaping, lighting, and signage must comply with the City of Knoxville Zoning Ordinance.
7. To the extent there is a conflict or ambiguity between the terms of any of the Project Documents, and notwithstanding anything to the contrary in the foregoing documents, the order of priority listed below will be used for purposes of resolving the conflict or ambiguity:
(1) The Approved Final Plan;
(2) The Approved Preliminary Plan, Planning File No. 9-A-21-PD, attached as Exhibit B;
(3) The City of Knoxville Zoning Code.
PROJECT DESCRIPTION
This proposal is for a 20,000 sqft, 3-story restaurant located on the southwest side of Willow Avenue, across from the Covenant Health Stadium, and within the boundary of the approved preliminary plan mixed-use stadium planned development (9-A-21-PD). The subject property was identified as being part of Phase 2, post-construction of the stadium, and is eligible to utilize the approved exceptions to the zoning regulations.
The total restaurant area provided by the applicant (20,000 sqft) includes the floor area within the structure and the usable ground level and rooftop patios, and second story decks. Approximately 75% of the proposed floor area is inside the structure, which includes the service areas.
ZONING EXCEPTIONS UTILIZED BY THE DEVELOPMENT
The following exceptions to the underlying dimensional, design, and use standards were approved as part of the preliminary plan for the multi-use stadium / mixed-use planned development. Please refer to the Planned Development Narrative (Exhibit B) provided by the applicant for additional information.
Items for which no exception was granted are required to comply with I-MU zoning standards and the other articles of the zoning ordinance as applicable. Items for which an exception was granted are reviewed for substantial conformance below. Under each exception, verification is provided that the proposal is in substantial conformance with the approved preliminary plan.
1. Dimensional Standards (Article 6.3). Three exceptions were approved from the I-MU dimensional standards. This proposal utilizes two: 175' maximum building height, and 0' minimum rear setback.
A. Maximum building height: The proposed building is 60'-6" to the highest point of the tower feature in the northwest corner of the building (main entrance).
B. Minimum rear setback: The proposed rear setback is 3' at the southeast corner of the building.
2. Required Off-Street Parking (Article 11.0). Exceptions were approved to eliminate the off-street parking and off-street loading requirements.
A. This proposal provides 15 parking spaces and no dedicated off-street loading spaces.
ADDITIONAL MEASUREMENTS
1. Building Coverage: Neither the I-MU zone nor the preliminary plan has any requirements for building coverage. However, per Article 16.7.F (Modifications to Approved Plans), if a modification to a plan resulted in a difference in the building coverage, it would require another round of approvals. A change to the building coverage on a lot amounting to less than 10% would require Planning Commission approval; a change to the building coverage greater than 10% would require City Council approval.
A. 20.4 percent coverage (building footprint only)
b. 30.7 percent coverage (including the outdoor patios and decks)
The proposal is in compliance with the preliminary plan for the planned development and with the other dimensional and design standards of the I-MU (Industrial-Mixed Use) district, and no nonconformities were identified by staff during this review.
If the Planning Commission approves the final plan, the application will go forward to the City Council for consideration of an amendment to the official zoning map to add the PD (Planned Development) designation.
Brad Salsbury
Case History
- October 27, 2025
Date Filed
- December 11, 2025
To be heard by the Planning Commission
- January 6, 2026
First Legislative Reading