Array
(
    [case] => 2-C-21-DT
)
$isadmin



2-C-21-DT | Design Review Board







































    
    
    
    
    
    
    
    


















Level II: Kress Building

2-C-21-DT

Approve Subject To Conditions

APPROVE Certificate 2-C-21-DT subject to the patio size and placement meeting all City requirements and a permissive use agreement to be obtained.
Recommendation
Staff recommends approval of Certificate 2-C-21-DT as submitted, with the condition that the patio size and placement meet all City requirements and a permissive use agreement is obtained.

Applicant Request
Level II: Exterior rehabilitation
    • Modifications to the Kress Building storefront to create an indoor/outdoor patio space. On the center storefront, the existing storefront glass and central doors will be removed; the existing bases and vertical frames will remain. The transom windows will also remain. The removed storefront windows will accommodate an indoor/outdoor patio in the central storefront, with a new storefront system recessed into the building. The recessed storefronts will feature black storefront to framing to match the existing adjacent storefronts, a transom above, and clear glazing. Recessed can lights in new ceilings will provide illumination for the patio.
    • A 28'-2" wide by 6' deep patio with a decorative steel railing will extend into the sidewalk.

Property Notes / Work to be Completed
    • The Kress Building is a contributing structure to the Gay Street Commercial Historic District, so the Historic Resources section of the design guidelines applies. All work is located on the center storefront; the left and right storefronts will not be modified in this proposal. The existing configuration is a modern replacement storefront system, reviewed by the DRB in February 2015.
    • While guidelines encourage storefronts to be maintained as they were originally, the proposed design retains the overall size, location, and proportion of the central storefront and does not introduce any new door or window elements to the storefront (which could introduce a contemporary or incompatible design). The existing storefront does not feature the bulkhead detail noted in the design guidelines, only an approximately 4-6" tall strip of horizontal framing. The existing transom will be retained, along with vertical elements of the framing. The sense of a "formal entrance to the front façade" is maintained in the design.
    • A new glass mezzanine level will be added to the interior of the storefront; it will be recessed from the existing façade and minimally visible through the divided-light transom windows.
    • As the building is listed on the National Register of Historic Places, the SOI Standards also apply. The overall "features, spaces, and spatial relationships" on the storefront are retained in the proposed storefront modification. Removing the glass for an open storefront retains the sense of transparency created by large storefront windows. If the indoor/outdoor patio element were removed in the future, the essential form and integrity of the Kress Building's façade would be retained. Glass storefront windows could be re-installed in the façade without further effect on the building. No historic materials or details will be removed or altered for the proposal; the historic terracotta elements will remain intact.
    • The property owner or tenant will need to secure a permissive use agreement with the City of Knoxville for the patio's extension into Gay Street.

Applicable Guidelines
Downtown Knoxville Design Guidelines
    • B. Private Realm
    • 1. Building Mass, Scale, and Form
    • 1a. Maintain a pedestrian-scaled environment from block-to-block.
    • 1c. Use building materials, cornice lines, signs, and awnings of a human scale in order to reduce the mass of buildings as experienced at the street level.
    • 3. Building Materials
    • 3b. Rehabilitate historic structures in accordance with the Secretary of the Interior's Standards.
    • C. Historic Resources
    • 1d. Do not alter, obscure, or destroy significant features of historic resources when constructing additions.
    • 2. Storefronts
    • Throughout downtown, historic buildings present a front elevation with an individual façade that is usually 25-35 feet wide. The storefronts are divided horizontally into three sections: bulkheads, solid or opaque, usually 18-24 inches tall; a plate glass storefront window 6-8 feet tall; and above it, a clear or patterned glass transom.
    • 2a. Restore and maintain storefronts as they were originally.
    • 3. Entrances
    • Formal entrances to front facades should be retained. Altering or removing the main entrance to grant street-level access is not appropriate.
    • 3a. Establish recessed entries, either rectangular or with slightly canted sides, which are appropriate in storefronts.
    • 3b. Allow for multiple entries on the first floor of the building, giving access to commercial space that may be divided into bays.
    • 3c. Maintain original height and materials for doors that are consistent with the use of the building, such as residential, commercial, or banking purposes.
    • 4. Windows
    • 4d. Maintain the relationship of solids to voids with new construction that is similar to other buildings in the district, including the typical width, height, spacing, and horizontal alignment of windows.
    • SOI Standards for Rehabilitation
    • 2. The historic character of a property will be retained and preserved. The removal of distinctive materials or alterations of features, spaces, and spatial relationships that characterize a property will be avoided.
    • 9. New additions, exterior alterations, or related new construction will not destroy historic materials, features, and spatial relationships that characterize the property. The new work shall be differentiated from the old and compatible with the historic materials, features, size, scale and proportion, and massing to protect the integrity of the property and its environment.
    • 10. New additions and adjacent or related new construction will be undertaken in such a manner that, if removed in the future, the essential form and integrity of the historic property and its environment would be unimpaired.
See Guidelines

Meeting Date
February 17, 2021

Kress Building
417 S. Gay St.
DK (Downtown Knoxville)

Applicant
Patrick Core
Owner Jackson Central Properties, LLC

Staff
Lindsay Lanois
Phone: 865-215-3795
Email: lindsay.lanois@knoxplanning.org

Case History

Date Filed
February 2, 2021
Case File

Date Heard
February 17, 2021
Case File

Case History