Property Information
−
+
Location8930 KEENBERG LN
West side of Keenberg Ln, south side of Emory Rd, east side of Old Cobbs Ferry Rd
Commission District 6
Size5.42 acres
Place Type DesignationTN (Traditional Neighborhood), HP (Hillside Ridgetop Protection)
Currently on the Property
Rural Residential
Growth PlanPlanned Growth Area
Fire Department / DistrictKarns Fire Department
- Utilities
SewerWest Knox Utility District
WaterWest Knox Utility District
Case Notes
−
+
Disposition Summary
Approved with Conditions
Approve the variance to reduce the K value from 25 to 20 on Road D STA 4+14.66.
A. Due to the existing steeper topography along Road D, a reduction of the vertical curve length is needed to keep site grading balanced.
B. The topography and shape of the property are unique and have not been created by any person having an interest in the property.
C. This is a road with low traffic volumes, and the variation is not great enough to cause detriment to public safety, health, or welfare, nor would it be injurious to other properties in the neighborhood. Knox County EPW recommends approval of this variance based on the justifications provided by the applicant.
Approve the variance to reduce the minimum length for the tangent connecting broken back horizontal curves from 150 ft to 29 ft on Road D from STA 5+54.26 to 5+83.41.
A. Due to the existing steeper topography along Road D and the TVA transmission tower, a reduction in tangent length is needed to construct the road.
B. The existing topography, shape of property, and TVA tower are unique and have not been created by any person having an interest in the property.
C. This is a road with low traffic volumes, and the variation is not great enough to cause detriment to public safety, health, or welfare, nor would it be injurious to other properties in the neighborhood. Knox County EPW recommends approval of this variance based on the justifications provided by the applicant.
Approve the variance to reduce the lot depth for double frontage lots 85-88 from 150 ft to 110 ft.
A. A 30-ft right-of-way easement is required by County Engineering in the rear of lots 85-88. This easement cannot be within common area. Without a common area buffer, a variance is required for the reduction in lot depth.
B. The right-of-way easement at this location is unique to this property.
C. The right-of-way easement is necessary for public safety, health, or welfare. Knox County EPW recommends approval of this variance based on the justifications provided by the applicant.
Approve the alternative design standards based on the justification provided by the applicant and recommendations of the Knox County Department of Engineering and Public Works.
Approve the Concept Plan subject to 8 conditions.
1. Connection to sanitary sewer and meeting other relevant utility provider requirements.
2. Providing street names consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Before certification of the final plat for the subdivision, establishing a property owners association or other legal entity responsible for maintaining common facilities, such as common areas, amenities, private roads, and/or stormwater drainage systems.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Meeting all applicable requirements of the Knox County Zoning Ordinance.
6. If during design plan approval or construction of the development, it is discovered that unforeseen off-site improvements within the right-of-way are necessary as caused by the development, the developer will either enter into a memorandum of understanding (MOU) with the County for these improvements or reimburse the County for their direct expenses (if completed by County crews) to make corrections deemed necessary.
7. Implementing the recommendations of the Hatmaker (Emory Green) Subdivision Transportation Impact Study (Fulghum MacIndoe, 10/26/2020), as revised and approved by Planning Commission staff and Knox County Engineering and Public Works (see Exhibit A).
8. All double frontage lots must meet the requirements of Section 3.02.A.4 of the Subdivision Regulations.
This proposal is a second revision to the Emory Green Subdivision west side of the townhomes (12-SD-20-C/12-F-20-UR). The Emory Green Subdivision is a newly constructed residential development with townhomes and single family homes at W Emory Road and Old Cobbs Ferry Road. The townhomes were constructed on one lot. This proposal is to subdivide the existing 30 townhomes on individual lots and create a private road that is 26 ft wide within a 40 ft right-of-way.