Subdivision

Concept Plan

5-SB-16-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 9 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard
APPROVE the Concept Plan subject to 8 conditions:


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Dept.
2. Provision of curbs on all JPEs as may be required by the Knox County Dept. of Engineering and Public Works
3. Provide an AASHTO approved turn around at the end of all JPEs
4. Meeting all other applicable requirements of the Knox County Department of Engineering and Public Works.
5. Prior to final plat approval, establish a homeowners association for the purpose of maintaining all of the JPEs, storm drainage facilities and all other commonly held assets
6. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County (Ord 91-1-102)
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation, Tenn. Valley Authority and the Army Corp of Engineers
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Arcadia
Lots
24 (Split)
Proposed Density
.47 du/ac
Residential?
Yes - SF

Variances

1. Horizontal curve variances from 250' to 200' at sta 6+00 & 8+75 of Road H
2. Horizontal curve variances from 250' to 150' at sta 45+50 & 49+00 of Arcadia Peninsula Wy., at sta. 0+75 & 4+00 of Road H.
3 Horizontal curve variance from 250' to 100' at sta 2+00 of Road H
4. Variances of broken back curve tangent length from 150' to 92' & at sta 6+13 to sta 7+05 of Road H
5. Variances of Roadway grade from 12% to 15% from sta 0+65 to1+73 on Road G & from sta 0+65 to 6+00 on Road F
6. Variance of intersection spacing between Stoppard View Ln. and Road F on Arcadia Peninsula Wy. from 125' to 81'
7. Variances of joint permanent easement pavement widths & cross sections from 26' & 22' to 20' at locations as shown
8. Vertical curve variances on Road F from 180' to 90' at sta 0+65 & from 425' to 255' at sta 6+00 of Road F
9. Vertical curve variances on Road G from 180' to 90' at sta 0+65 & from 507.5' to 310' at sta 3+35 of Road G


Property Information

+
Location
Southwest end of Arcadia Peninsula Wy., southwest of Stoppard View Wy.

Commission District 5


Size
51.12 acres

Sector
Southwest County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 9 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the Concept Plan subject to 8 conditions:

1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Dept.
2. Provision of curbs on all JPEs as may be required by the Knox County Dept. of Engineering and Public Works
3. Provide an AASHTO approved turn around at the end of all JPEs
4. Meeting all other applicable requirements of the Knox County Department of Engineering and Public Works.
5. Prior to final plat approval, establish a homeowners association for the purpose of maintaining all of the JPEs, storm drainage facilities and all other commonly held assets
6. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County (Ord 91-1-102)
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation, Tenn. Valley Authority and the Army Corp of Engineers
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 - 9 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard
APPROVE the Concept Plan subject to 8 conditions:

Details of Action
1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Dept.
2. Provision of curbs on all JPEs as may be required by the Knox County Dept. of Engineering and Public Works
3. Provide an AASHTO approved turn around at the end of all JPEs
4. Meeting all other applicable requirements of the Knox County Department of Engineering and Public Works.
5. Prior to final plat approval, establish a homeowners association for the purpose of maintaining all of the JPEs, storm drainage facilities and all other commonly held assets
6. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County (Ord 91-1-102)
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation, Tenn. Valley Authority and the Army Corp of Engineers
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Arcadia

Beacon Park, LLC


Case History