Level II: N/A
6-A-13-HZ
Approved
Recommendation
Applicant Request
Guttering; Parking lot or driveway paving; Roofing; Signs- Work description for 5 buildings: The William Blount Mansion with 3 associated outbuildings and the Craighead-Jackson House located across the driveway to the east of the Mansion.
- Work on the exterior consists of roof replacement with new Alaskan yellow cedar grade "A" clear heartwood 100% edge grain shingles. Thickness: handsplit or hewn and rehewn 1/2" butt minimum with sawn taper to 1/4" min. Length: +/- 26". Shingle exposure and width to be field-verified to match existing.
- Existing copper gutters and downspouts to be repaired or replaced. Flashings: Lead-coated copper. Roof work & downspout repair will take place on all ?ve buildings.
- Some excavation will be required to run a new electrical service, new electrical conduit for exterior power, and a new water line for a new ?re protection system in the "mansion". The existing main distribution panel on the of?ce outbuilding will be removed and a new main distribution panel will be installed in the basement of Blount Mansion.
N/A
- Style:
Meeting Date
June 20, 2013
COA Expires May 20, 2015
N/A
200 W Hill Ave 37901
Applicant
Henry Henry Lafferty, P.A. - Joseph K. Opperman, Architects Joseph K. Opperman, Architects
Owner Gov. William Blount Mansion Association
Case History
Date Filed
May 13, 2013
Date Heard