Subdivision

Concept Plan

6-SD-19-C

Recommended for approval
by the Planning Commission

APPROVE variance 1 because the site conditions restrict compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.

APPROVE the Concept Plan subject to 9 conditions:


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
OT Tindell Farm
Lots
31 (Split)
Proposed Density
4.70 du/ac
Residential?
Yes - SF

Variances

VARIANCE REQUIRING PLANNING COMMISSION APPROVAL:
1. Reduction of vertical curve length on Road A at STA 0+80, from 203.5' to 125'.

APPROVED WAIVER:
1. Intersection grade waiver on Road A, from 1% up to 2.41% except in the area where the pedestrian crossing must meet ADA requirements.


Property Information

+
Location
1108 E Beaver Creek Dr

South side of E. Beaver Creek Drive, West of Dry Gap Pike

Commission District 7
Census Tract 62.07


Size
6.59 acres

Sector
North County

Currently on the Property
Residence and vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variance 1 because the site conditions restrict compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.

APPROVE the Concept Plan subject to 9 conditions:

1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Department.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. The site's frontage along E. Beaver Creek Dr. shall be graded for a future sidewalk. The intersection grade shall be adjusted so that the pedestrian street crossing will comply with the Americans with Disabilities Act (ADA) standards.
4. Installation of sidewalks as identified on the concept plan. Sidewalks shall meet all applicable requirements of the Americans with Disabilities Act and the Knox County Department of Engineering and Public Works. A bond shall be provided to the Knox County Department of Engineering and Public Works by the developer in an amount sufficient to guarantee the installation of the sidewalks.
5. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation and the U.S. Army Corps of Engineers for any alteration to the existing pond and designated wetland on the site. The final determination regarding the proposed alteration of these features may require a modification of the layout of the subdivision.
6. Obtaining any off-site drainage easement that may be required for the discharge from the stormwater pond located between Lots 18 and 19.
7. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
8. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the common area and drainage system.
9. Submitting to Planning staff prior to final plat review by the Planning Commission, the certification of design plan approval form as required by the Knoxville-Knox County Subdivision Regulations.
Disposition Summary
APPROVE variance 1 because the site conditions restrict compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.

APPROVE the Concept Plan subject to 9 conditions:

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

OT Tindell Farm

Trantanella Construction Co.


Case History