Subdivision

Concept Plan

6-SH-01-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-10 because of topography, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 10 conditions:


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Drainage retention being designed pursuant to Knox County's sinkhole policy.
4. On the final plat, identify sight distance easements across Lots 56, 79 and 89.
5. Certification on the final plat by the applicant's surveyor that there is the required sight distance in both directions along Maloneyville Rd.
6. Place a note on the final plat that all lots will have access only to the internal street system.
7. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
8. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation for any alteration to the blueline stream.
9. Meeting all requirements of the approved Use-on-Review development plan.
10. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Amberwood ( Formerly Grove Park)
Lots
88 (Split)
Proposed Density
3.96 du/ac

Variances

1. Horizontal curve variance on Road A at station 6+50, from 250' to 100'.
2. Horizontal curve variance on Road A at station 12+00, from 250' to 100'.
3. Horizontal curve variance on Road C at station 3+00, from 250' to 100'.
4. Vertical curve variance on Road C at station 9+83, from 157.5' to 150'.
5. Intersection grade variance on Road A at Road C, from 1% to 2%.
6. Intersection grade variance on Road E at Maloneyville Rd., from 1% to 2%.
7. Intersection grade variance on Road E at Road C, from 1% to 3.%.
8. Intersection grade variance on Road D at Road A, from 1% to 2%.
9. Reverse curve tangent length variance on Road D at station 3+00 from 50' to 30.88'.
10. Broken back curve variance on Road D at station 1+75, from 150' to 37.71'.


Property Information

+
Location
West side of Maloneyville Rd., north of Washington Pike.

Commission District 8


Size
28 acres

Sector
Northeast County

Currently on the Property
Vacant land

Growth Plan
Rural Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-10 because of topography, and the proposed variances will not create a traffic hazard.


APPROVE the Concept Plan subject to 10 conditions:

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Drainage retention being designed pursuant to Knox County's sinkhole policy.
4. On the final plat, identify sight distance easements across Lots 56, 79 and 89.
5. Certification on the final plat by the applicant's surveyor that there is the required sight distance in both directions along Maloneyville Rd.
6. Place a note on the final plat that all lots will have access only to the internal street system.
7. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
8. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation for any alteration to the blueline stream.
9. Meeting all requirements of the approved Use-on-Review development plan.
10. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1-10 because of topography, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 10 conditions:

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Drainage retention being designed pursuant to Knox County's sinkhole policy.
4. On the final plat, identify sight distance easements across Lots 56, 79 and 89.
5. Certification on the final plat by the applicant's surveyor that there is the required sight distance in both directions along Maloneyville Rd.
6. Place a note on the final plat that all lots will have access only to the internal street system.
7. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
8. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation for any alteration to the blueline stream.
9. Meeting all requirements of the approved Use-on-Review development plan.
10. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Amberwood ( Formerly Grove Park)

William J. Farnham


Case History