7-D-23-DT | Design Review Board







































    
    
    
    
    
    
    
    


















Level I: Hilton Parking Garage

7-D-23-DT

Approve Subject To Conditions

APPROVE Certificate 7-D-23-DT, subject to the following condition: 1) signs and awnings to meet relevant aspects of City zoning code and building codes, including the necessary revision or after-the-fact variance granting approval of awning on Clinch Avenue.
Recommendation
Staff recommends approval of Certificate 7-D-23-DT, subject to the following conditions: 1) parking signs to be reduced in size, with approval by staff; 2) signs and awnings to meet relevant aspects of City zoning code and building codes, including the necessary revision or after-the-fact approval of awning on Clinch Avenue.

Applicant Request
Level I: Signs, awnings
c.1980, concrete parking garage.
    • New signs for parking garage; new flat metal awnings. Awning review is after-the-fact; awnings have already been installed. The awning on Walnut St measures 5' wide and 28' long, and is installed 9.25' above the sidewalk. The awning on Clinch Ave measures 5' wide and 28' long, and is currently installed at 8'-6" above the sidewalk level.
    • Both signs measure 36" wide by 120" tall (30 sq. ft.), and are internally illuminated, with push-through lights spelling Public Parking. The sign on Walnut St is 11'-6" above the sidewalk, and the sign on Clinch Ave is 10'-10" above the sidewalk. The applicant intends to install the new signs in the same location as the existing projecting signs.

Property Notes / Work to be Completed
    • The guidelines for the Grid District recommend projecting signs on modest size (9 sq. ft.), with larger signs approved by the Board. New projecting signs approved by the Board are typically around 11-15' sq. ft., with the largest projecting signs approved for businesses on Gay Street. The existing signs were installed prior to the creation of the Downtown Design Review Board and do not conform with the design guidelines. The new signs, both at 30 sq. ft., serve to indicate a parking garage, and should be reduced in size to meet the design guidelines. The internal illumination indicated on the sign drawings meets the guidelines and past Board approvals. The signs should meet the relevant aspects of the City sign code (13.5.B), with its width not extending closer than 20" to the curb.
    • The awnings were installed without the required City permits and design review approval. Awnings should meet the relevant aspects of the City zoning code, including 10.3.F, which requires a vertical clearance of at least 9' from the sidewalk, not to exceed more than two-thirds width of the sidewalk. The Clinch Avenue awning does not currently meet code as installed, located 8'-6" above the sidewalk, and will need to seek a variance or be removed and reinstalled at least 9' above the sidewalk. Awnings, as installed or revised, should meet the relevant aspects of the City zoning code and building codes.

Applicable Guidelines
Downtown Design Guidelines
    • B. Private Realm
    • 1. Building Mass, Scale and Form
    • 1c. Use building materials, cornice lines, signs, and awnings of a human scale in order to reduce the mass of buildings as experienced at the street level.
    • B. The Traditional Grid District
    • 1. Recommended Signs
    • 1b. Projecting signs of modest size (9 square feet, maximum); a larger sign must be approved by the board.
See Guidelines

Meeting Date
July 19, 2023

Hilton Parking Garage
500 Clinch Ave.
DK (Downtown Knoxville)

Applicant / Owner
Knoxville Properties Partnership Jerrod Herron

Staff
Lindsay Lanois
Phone: 865-215-3795
Email: lindsay.lanois@knoxplanning.org

Case History

Date Filed
June 27, 2023

Date Heard
July 19, 2023
Case File

Case History