Level II: Edgewood-Park City H
7-H-21-HZ
Approved With Conditions
Recommendation
Staff recommends approval of the work as submitted, with the following conditions:1) new west elevation window header to align with adjacent window, with specifications for window to be submitted to staff for approval, including placement and trim details;
2) final specifications for porch roof height, dimensions of portico gable, and fascia details to be submitted to staff.
Applicant Request
Additions; Doors; Guttering; Porch; Siding; Windows- Exterior rehabilitation and addition of new front porch. Exterior rehabilitation scopes include: removal of non-historic aluminum siding and shutters; repair and replacement in-patches as necessary to historic wood siding below (with dimensions and design to match existing); replacement of gutters.
- On the right (west) elevation, a secondary entry with a concrete stoop, concrete access stairs, and wrought-iron railing will be removed. Applicant proposes a new one-over-one, double-hung wood window with the same dimensions as other side elevation windows to be installed in its place.
- Removal of non-historic gable-roof portico centered over the primary entry. A new front porch, measuring 8' deep by 27.5' wide, will extend the full length of the façade (north), featuring a 3/12 hipped roof with a front gable centered over the primary entry. The porch will be supported by four 8' tall round wood columns, 8" in diameter and evenly spaced along the façade. The new concrete porch foundation will be approximately 4" tall, with a wood beadboard ceiling and wood fascia and frieze boards to match the original fascia and frieze details on the house.
- Conditions of approval of 7/15/2021 HZC meeting: 1) west elevation window can be installed at same height of existing secondary door, with final window specifications to be submitted to staff for approval. 2) 2) final specifications for porch roof height, dimensions of portico gable, and fascia details to be submitted to staff in a scaled drawing.
Edgewood-Park City H
- Style: Queen Anne, c.1900
- One-and-one-half-story frame residence with a hipped roof clad in asphalt shingles, an exterior of aluminum siding, and a continuous foundation. Two gable-roof dormers are evenly spaced on the front roof slope. Centrally-located, front-gable roof portico.
- Style: Queen Anne, c.1900
Applicable Guidelines
Edgewood-Park City Design Guidelines, adopted by the Knoxville City Council on July 29, 1997.
See Guidelines- Roofs
- 1. Make the shape and pitch of roofs on new construction imitate the shape and pitch of roofs on neighboring existing houses or other houses of the same architectural style. Replacement roofs must copy the shape and pitch of original roofs, and the soffit, fascia, and trim detail between roof and wall should mimic the original.
- 2. The eaves on additions or new buildings shall have an overhang that mimics the original eaves.
- Porches
- 1. Porches on historic houses shall be repaired or replicated using wood materials for ceilings and floors, balustrades, posts and columns that duplicate the original size and design. Reconstruction of the documented original porch is appropriate.
- 2. New buildings constricted in Edgewood-Park City must contain front porches large enough to provide seating. The proportion of the porches to the front facades is to be consistent with the historic porches in the neighborhood. Details such as columns, posts, piers, balustrades and porch flooring and ceilings will be built with materials that are consistent in appearance with historic materials.
- Wall Coverings: Wood
- 2. Replacement siding, trim, and patterned shingles shall duplicate the original.
- 4. Repair wooden features by patching, piecing-in, or otherwise reinforcing the wood. Repair may also include limited replacement with matching or compatible substitute materials, when elements remain and can be copied.
- 7. An entire wooden feature that is too deteriorated to repair or is completely missing must be replaced in kind. If features are replaced, the materials they are made from shall be compatible with the original in size and scale. Replacement parts must be based on historical, pictorial, and physical documentation. If documentation does not exist, a new sympathetically designed feature would be better than a hypothetical 'old' one.
Meeting Date
July 15, 2021
COA Expires July 15, 2024
Edgewood-Park City H
1800 Jefferson Ave. 37917
Applicant / Owner