Subdivision

Concept Plan

7-SB-20-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-3 because topographic constraints and site conditions restrict compliance with the Subdivision Regulations and will not create a traffic hazard.

APPROVE the alternate design standard based on the recommendations of the Knox Count


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
South Creek
Lots
99 (Split)
Proposed Density
3.97 du/ac
Residential?
Yes - SF

Variances

VARIANCES REQUIRING PLANNING COMMISSION APPROVAL:

1) Reduction of vertical curve K value from 25 to 20, Sweetwater Lane at VPI STA 7+09.58.
2) Reduction of vertical curve K value from 25 to 20, Sweetwater Lane at VPI STA 9+89.49.
3) Reduction of a tangent for broken back curve from 150? to 85?, Sweetwater Lane at STA 5+61.66.

ALTERNATIVE DESIGN STANDARDS REQUIRING PLANNING COMMISSION APPROVAL:

1) Reduction of horizontal curve radius on Sweetwater Lane from 250 feet to 200 feet at STA 6+47.49.


ALTERNATIVE DESIGN STANDARDS APPROVED BY KNOX COUNTY ENGINEERING AND PUBLIC WORKS:

1) Reduction of right-of-way width from 50? to 40?.


Property Information

+
Location
0 , 107, 115, 121, 125, 201, 204, & 205 Sweetwater Ln.

South of Henry Haynes Rd., northwest side of Tipton Station Rd. at W.Hendron Chapel Rd.

Commission District 9


Size
24.95 acres

Sector
South County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-3 because topographic constraints and site conditions restrict compliance with the Subdivision Regulations and will not create a traffic hazard.

APPROVE the alternate design standard based on the recommendations of the Knox Count

1) Connection to sanitary sewer and meeting any other relevant requirements of the utility provider.
2) Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3) Meeting all applicable requirements of Knox County Engineering and Public Works.
4) A final plat application based on this concept plan will not be accepted for review until certification of design plan approval has been submitted to Planning staff.
Disposition Summary
APPROVE variances 1-3 because topographic constraints and site conditions restrict compliance with the Subdivision Regulations and will not create a traffic hazard.

APPROVE the alternate design standard based on the recommendations of the Knox Count

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

South Creek

YSOS Holdings, LLC


Case History