Rezoning

9-F-26-RZ

Planning Staff Recommendation

Deny the RN-2 (Single-Family Residential Neighborhood) zoning district due to environmental constraints. The HP (Hillside Protection Overlay) district would be retained.


Request

Property Info

Case Notes

What's next?

Applicant Request

+

Property Information

+
Location
3221 GREENWAY DR

North side of Greenway Dr, east of N Broadway

Council District 4


Size
0.76 acres

Planning Sector
North City

Land Use Classification LDR (Low Density Residential), HP (Hillside Ridgetop Protection) LDR (Low Density Residential), HP (Hillside Ridgetop Protection)


Currently on the Property
Single Family Residential

Growth Plan
N/A (Within City Limits)

Fire Department / District
Knoxville Fire Department

Case Notes

+

Staff Recommendation
Deny the RN-2 (Single-Family Residential Neighborhood) zoning district due to environmental constraints. The HP (Hillside Protection Overlay) district would be retained.
PURSUANT TO THE CITY OF KNOXVILLE ZONING ORDINANCE, SECTION 16.1.E, ALL OF THE FOLLOWING CONDITIONS MUST BE MET FOR ALL REZONINGS:

THE PROPOSED AMENDMENT IS NECESSARY BECAUSE OF SUBSTANTIALLY CHANGED OR CHANGING CONDITIONS IN THE AREA AND DISTRICTS AFFECTED, OR IN THE CITY GENERALLY.
1. There has been a notable increase in residential development along the north side of Greenway Drive over the last 10 years, consisting of single-family dwellings on 20,000 sq ft to 1.5-acre lots at the base of the ridge.
2. Since 2020, there has been a minor increase in residential density along Greenway Drive, with rezonings from the RN-1 (Single-Family Residential Neighborhood) district to the RN-2 (Single-Family Residential Neighborhood), RN-3 (General Residential Neighborhood), and RN-4 (General Residential Neighborhood) districts. However, all but one of the rezonings were located on the south side of Greenway Drive, where the land is flatter. Properties fronting Greenway Drive on the north side are partially on a ridge and are consequently constrained with severe slopes.
3. The one rezoning on the north side of Greenway Drive, west of the subject property, was for three lots totaling 5.5 acres that were later subdivided into 20,000+ sq ft lots (12-D-20-RZ).

THE PROPOSED AMENDMENT IS CONSISTENT WITH THE INTENT AND PURPOSES OF THIS CODE.
1. The RN-2 district is intended to accommodate low-density single-family residential development on relatively small lots with smaller setbacks. Two-family dwellings may also be allowed by special use approval.
2. Rezonings should be based on the entire range of uses allowed within a zone to ensure that any development brought forth at a future time would be compatible with the surrounding land uses. The RN-1 and RN-2 zoning districts permit the same uses.
3. The subject property is within the HP (Hillside Protection Overlay) district and is relatively steep, with the majority of the site constrained by slopes in the 25%-40% and above 40% ranges. The recommended disturbance budget for the property is approximately 8,400 sq ft, which has nearly been met with the existing dwelling on the site. It is not possible to subdivide and add another structure to the site without exceeding the disturbance limit of the HP overlay district.

THE PROPOSED AMENDMENT SHALL NOT ADVERSELY AFFECT ANY OTHER PART OF THE CITY, NOR SHALL ANY DIRECT OR INDIRECT ADVERSE EFFECTS RESULT FROM SUCH AMENDMENT.
1. The primary difference between the existing RN-1 zoning district and the requested RN-2 district is the dimensional standards. The RN-1 district requires a minimum lot area of 10,000 sq ft with larger setbacks, whereas the RN-2 district requires a minimum lot area of 5,000 sq ft with smaller setbacks. The RN-2 district at this location would permit residential development that is out of character with the development trends on the north side of Greenway Drive, which consists of lots larger than 10,000 sq ft with larger setbacks and structures clustered at the base of the ridge.

THE PROPOSED AMENDMENT SHALL BE CONSISTENT WITH AND NOT IN CONFLICT WITH THE KNOXVILLE-KNOX COUNTY GENERAL PLAN AND ITS COMPONENT PARTS, INCLUDING ADOPTED SECTOR PLANS, CORRIDOR PLANS, AND RELATED DOCUMENTS.
1. The subject property is designated LDR (Low Density Residential) under the City's One Year Plan and North City Sector Plan, which permits consideration of the RN-2 zoning district.
2. The proposed rezoning is not consistent with the General Plan's Development Policy 6.3: Encourage development in areas with the fewest environmental constraints. The subject property is a 75-ft wide lot that is largely steep hillside, which does not support increasing residential density at this site.

WHETHER ADEQUATE PUBLIC FACILITIES ARE AVAILABLE INCLUDING, BUT NOT LIMITED TO, SCHOOLS, PARKS, POLICE AND FIRE PROTECTION, ROADS, SANITARY SEWERS, STORM SEWERS, AND WATER LINES, OR ARE REASONABLY CAPABLE OF BEING PROVIDED PRIOR TO THE DEVELOPMENT OF THE SUBJECT PROPERTY IF THE AMENDMENT WERE ADOPTED.
1. This is an urbanized area with ample utility and facility infrastructure to support a rezoning of this site.

What's next?

+
Knoxville City Council
October 13, 2026

October 27, 2026
Applicant

Noah Hudson


Case History