Subdivision

Concept Plan

1-SC-08-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 5 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 7 conditions:


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
4. Certification on the final plat by the applicant's surveyor that there is 300 feet of sight distance in both directions along Tooles Bend Rd.
5. Place a note on the final plat that all lots will have access only to the internal street system.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the joint permanent easement, common areas, storm drainage system and any other commonly held assets.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Villas at Tooles Bend
Lots
12 (Split)
Proposed Density
3.00 du/ac
Residential?
Yes - SF

Variances

1. Horizontal curve variance from 150' to 122' at sta 3+40 of Road A
2. Vertical curve variance from 262.5' to 210' at sta. 2+73 of Road A
3. Vertical curve variance from 200' to 120'' at sta. 1+02 of Road A
4. Variance of intersection spacing on Tooles Bend Rd. from 300' to 108' between Road A and Amberleigh Dr.
5. Variance of intersection spacing on Tooles Bend Rd. from 300' to 173' between Road A and Badgett Rd.


Property Information

+
Location
East side of Tooles Bend Rd., north side of Badgett Rd.

Commission District 4


Size
4 acres

Sector
Southwest County

Currently on the Property
Residence and vacant land

Growth Plan
Rural Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 5 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.


APPROVE the Concept Plan subject to 7 conditions:

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
4. Certification on the final plat by the applicant's surveyor that there is 300 feet of sight distance in both directions along Tooles Bend Rd.
5. Place a note on the final plat that all lots will have access only to the internal street system.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the joint permanent easement, common areas, storm drainage system and any other commonly held assets.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 - 5 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 7 conditions:

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
4. Certification on the final plat by the applicant's surveyor that there is 300 feet of sight distance in both directions along Tooles Bend Rd.
5. Place a note on the final plat that all lots will have access only to the internal street system.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the joint permanent easement, common areas, storm drainage system and any other commonly held assets.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Villas at Tooles Bend

Forest Brook Development


Case History