Subdivision

Concept Plan

10-SG-15-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-4 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 5 conditions:


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Willows Pointe Subdivision (FKA - Twin Willows Subdivision)
Lots
69 (Split)
Proposed Density
2.56 du/ac
Residential?
Yes - SF

Variances

1. Vertical curve variance on Road A at STA 1+00, from 300' to 180'.
2. Street grade variance on Road A, from STA 0+80 to STA 7+75, from 12% to 15%.
3. Horizontal curve variance on Road C at STA 3+50, from 250' to 100'.
4. Horizontal curve variance on Road C at STA 8+50, from 250' to 100'.


Property Information

+
Location
0 Buttermilk Rd

Southeast side of Buttermilk Rd., west of Graybeal Rd.

Commission District 6
Census Tract 59.09


Size
26.92 acres

Sector
Northwest County

Currently on the Property
Vacant land

Growth Plan
Rural Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-4 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 5 conditions:

1. Meeting all relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. The surveyor providing certification on the final plat that a minimum of 300' of sight distance exists and can be maintained at the subdivision entrance onto Buttermilk Rd. in both directions along Buttermilk Rd.
4. Placing a note on the final plat that all structures will have to be located at least 50' from the top of the sinkhole (closed contour area) identified on the plat. Building construction within the 50' setback may be permitted if a geotechnical study prepared by a registered engineer states that building within the 50' sinkhole buffer is acceptable and the study is approved by the Knox County Department of Engineering and Public Works. The geotechnical study must be completed and submitted to Knox County Department of Engineering and Public Works prior to submission of the final plat for Lots 41-44 since these lots do not have a building area outside of the 50' setback area. A 5' drainage easement extending outside of the uppermost closed contour is required. Building construction is not permitted within the hatchered contour area of the sinkhole or the drainage easement. Engineered footings may be required for any structures within the 50' sinkhole buffer.
5. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.

With the conditions noted, this plan meets the requirements for approval of a Concept Plan.
Disposition Summary
APPROVE variances 1-4 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 5 conditions:

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Willows Pointe Subdivision (FKA - Twin Willows Subdivision)

Twin Willows Construction


Case History