Design Review Board

Oakwood/Lincoln Park Infill Housing Overlay District

2-C-25-IH

Staff Recommendation

The Board should discuss the proposed width and scale of the house in the neighborhood context. If determined to be appropriate, conditions of approval should include: 1) parking to be revised to meet design guidelines, with final site plan meeting City Engineering standards; 2) front porch to be increased to 8' in depth; 3) additional window to be added to left side elevation and right side window to be revised to double-hung window; 4) final construction to retain details shown in drawing; 5) final site plan should include new native or naturalized trees in front and rear yards.


Location
342 Chickamauga Ave. 37917

Owner
Atomic City Partners LLC Atomic City Partners LLC

Applicant Request
New Primary Structure
1. The house is proposed to be set 36.5' from the front property line. The average front setback of the blockface is 35.8'. The proposed front setback will maintain a consistent front setback with the blockface. The site plan includes a walkway from the house to the street.

2. The street to receive new construction is characterized by Minimal Traditionals, modified Queen Anne cottages, Craftsman bungalows, and ranch houses. The 16' wide by 40' deep house is not proportionate to the other houses on the block or the lot. Other houses on the block range between approximately 24' and 58' wide. Side setback requirements would allow for a house with a wider façade. The Board should discuss the proposed building width.

The applicant has used the proposed plan previously; the staff report noted the narrow width of the building but there were five comparable shotgun houses on the block.

3. Infill Housing design guidelines state that driveways from the front of the house should not be permitted on streets with alleys. Parking is a concrete pad next to the front of the house and is accessed from the street. Parking should be revised so that it is accessed from the alley. The final site plan should meet City Engineering standards.

4. The two-bay, two-story façade is more narrow than other houses on the street by at least 5'-8.'

5. The house features a full-length 6' deep front porch, which should be increased to at least 8' to meet the design guidelines. The 8 by 8 columns and horizontal header add detail to the porch design. The engaged gable on the front porch should be included in the final construction. If the front porch is constructed on an open foundation, the lattice indicated on the plans should be included to avoid an open deck look.

6. Guidelines recommend window and door styles be similar, with similar proportions and ratio of solid to void, to historic houses on the block. At least one additional window should be added to the left side elevation to reduce the large swath of siding with no transparency. The frontmost windows on the right elevation should be double-hung windows instead of transoms.

7. The proposed 10/12 pitch roof meets the design guidelines. The final construction should incorporate the rake mold and eave overhangs as drawn.

8. The application does not include information on siding or roofing materials. If vinyl siding is used, the siding should feature an overlap instead of Dutch lap or flush panel siding. The stucco coated block foundation meets the design guidelines.

9. The final site plan should include one native or naturalized shade tree in the front and rear yards.

Staff Comments
New primary residence fronting Chickamauga Avenue. Two story residence features a front gable roof (10/12 pitch), an exterior of horizontal siding (material unspecified) with corner boards, and a block foundation clad in stucco. The house measures 40' long by 16' wide (20' wide with a 4' massing recessed towards the rear) and is proposed to be set 36.5' from the front property line (with a full-length porch set 30.5' from the front property line. The 6' deep front porch recessed under a shed roof with an engaged front-gable accent over the door that is supported by three 8" square posts. Parking is an 18' wide concrete driveway in front of the house and is accessed from Chickamauga Avenue.

The façade (northwest) features two bays on the first story, with paired 1/1 double hung windows in the first bay, followed by a full-light door with a transom. Paired 1/1 double hung windows are centrally located on the second story of the façade. A 1/1 double hung window is also visible on the side-gable massing which projects from the right side of the house, approximately 12' behind the façade. The left elevation features a secondary opening to a small porch, with one 1/1 double hung window on the second story. The right elevation features a one-story, side-gable massing projecting from the center of the elevation, and there are two transom windows and a 1/1 double hung window on the first story, with none on the second . The rear elevation has two 1/1 double hung windows on the first story and one pair of 1/1 double hung windows on the second story.

Notes on the plan reference previous cases' conditions of approval but the changes are not shown.
Applicant

Josh Josh Braden - Braden Family Properties LLC Braden Family


Planning Staff
Lindsay Lanois
Phone: 865-215-3795
Email: lindsay.lanois@knoxplanning.org