Subdivision

Concept Plan

2-SC-03-C

Approved
by the Planning Commission

APPROVE variances 1-7 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

DENY variance 8

APPROVE the concept plan subject to 10 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. Compaction of fill areas to be done in accordance with the requirements of the Knox County Dept. of Engineering and Public Works.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Providing a 1% grade at the intersection of Road B with Road A.
6. Changing the proposed road cross section to call-out the use of "D mix" asphalt on Roads A & B
7. Place a note on the final plat that vehicular access to all lots is limited to the internal street system.
8. Meeting all requirements of the approved Use-on-Review development plan.
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
10. Approval of the rezoning of this site to PR (Planned Residential) at an appropriate density by the Knox County Commission.

Applicant Request

+
Subdivision
Graybeal Crossing Subdivision
Lots
19 (Split)
Proposed Density
2.84 du/ac

Variances

1. Variance of intersection spacing between Road A and Hill Rd. from 300' to 109'.
2 Variance of intersection spacing between Road A and Salem Church Rd. from 300' to 95'.
3. Variance of tangent length between reverse curves from 50' to 16' at sta. 23+25 of Road B.
4. Vertical curve from 300' to 100' at sta. 10+50 of Road A.
5. Vertical curve from 180' to 100' at sta. 20+50 of Road B.
6. Broken back curve tangent from 150 to 60' between curves 3 and 4.
7. Horizontal curve variance from 250' to 150' at curves 3, 4 & 5.
8. Grade at intersection from 1% to 0% on Road B at Road A.


Property Information

+
Location
Southeast side of Hill Rd., south side of Fort Sumter Rd.

Commission District 7


Size
6.70 acres

Sector
North County

Currently on the Property
Single family residence & vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-7 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

DENY variance 8

APPROVE the concept plan subject to 10 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. Compaction of fill areas to be done in accordance with the requirements of the Knox County Dept. of Engineering and Public Works.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Providing a 1% grade at the intersection of Road B with Road A.
6. Changing the proposed road cross section to call-out the use of "D mix" asphalt on Roads A & B
7. Place a note on the final plat that vehicular access to all lots is limited to the internal street system.
8. Meeting all requirements of the approved Use-on-Review development plan.
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
10. Approval of the rezoning of this site to PR (Planned Residential) at an appropriate density by the Knox County Commission.
Disposition Summary
APPROVE variances 1-7 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

DENY variance 8

APPROVE the concept plan subject to 10 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. Compaction of fill areas to be done in accordance with the requirements of the Knox County Dept. of Engineering and Public Works.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Providing a 1% grade at the intersection of Road B with Road A.
6. Changing the proposed road cross section to call-out the use of "D mix" asphalt on Roads A & B
7. Place a note on the final plat that vehicular access to all lots is limited to the internal street system.
8. Meeting all requirements of the approved Use-on-Review development plan.
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
10. Approval of the rezoning of this site to PR (Planned Residential) at an appropriate density by the Knox County Commission.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Graybeal Crossing Subdivision

Prestige Development


Case History