Subdivision

Concept Plan

2-SI-07-C

Recommended for approval
by the Planning Commission

DENY variance 1 because the requested variance can be easily brought into conformance with the requirements

APPROVE the concept plan subject to 16 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
2. Provision of street names which are consistent with the Uniform Street Naming and Numbering System for Knox County (Ord. 91-1-102).
3. Correct the vertical curve to meet the requirements as noted in variance request #1.
4. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation (TDEC).
5. Provision of a 70' wide stream buffer along Beaver Creek (35' either side of the center of the creek)
6. Provide concrete piping under Road G to carry the Beaver Creek flow
7. Provide traffic calming as may be required by the Knox county Dept. of engineering and Public Works
8. Provide Minimum Floor Elevations (MFE) for each lot along Beaver Creek or as may be required by the Knox County Engineer
9. Provide the sidewalks as shown on the plan. All sidewalks must be a minimum of 4' wide and constructed to meet the requirements of the Americans With Disabilities Act.
10. Prior to final plat approval, the applicant shall work with Knox County Schools Administration regarding the provision of a sidewalk to connect this development with the newly constructed Gibbs Elementary School. If desired by the school system, the developer will be responsible for all costs associated with making this connection.
11. Place a note on the concept plan that intersection grades of 3% or less as shown on the plan have been approved by the Knox county Dept. of Engineering and Public Works
12. Creating a pavement taper along the frontage of lot 126 to align with the pavement along the Road A frontage of lot 121
13. Review and approval of the Road E eyebrow design by the Knox County Dept. of Engineering and Public Works.
14. Extending the boulevard section on Road A to Road B
15. Meeting all other applicable requirements of the Knox County Dept. of Engineering and Public Works.
16. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC Staff.

Applicant Request

+
Subdivision
Edwards Place
Lots
187 (Split)
Proposed Density
3.47 du/ac
Residential?
Yes - SF

Variances

1. Vertical curve variance from 103' to 100' at sta 0+65 of Road A


Property Information

+
Location
Southeast side of Thompson School Rd., southeast of Karnes Rd.

Commission District 8


Size
54 acres

Sector
Northeast County

Currently on the Property
Residence & vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
DENY variance 1 because the requested variance can be easily brought into conformance with the requirements

APPROVE the concept plan subject to 16 conditions

1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
2. Provision of street names which are consistent with the Uniform Street Naming and Numbering System for Knox County (Ord. 91-1-102).
3. Correct the vertical curve to meet the requirements as noted in variance request #1.
4. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation (TDEC).
5. Provision of a 70' wide stream buffer along Beaver Creek (35' either side of the center of the creek)
6. Provide concrete piping under Road G to carry the Beaver Creek flow
7. Provide traffic calming as may be required by the Knox county Dept. of engineering and Public Works
8. Provide Minimum Floor Elevations (MFE) for each lot along Beaver Creek or as may be required by the Knox County Engineer
9. Provide the sidewalks as shown on the plan. All sidewalks must be a minimum of 4' wide and constructed to meet the requirements of the Americans With Disabilities Act.
10. Prior to final plat approval, the applicant shall work with Knox County Schools Administration regarding the provision of a sidewalk to connect this development with the newly constructed Gibbs Elementary School. If desired by the school system, the developer will be responsible for all costs associated with making this connection.
11. Place a note on the concept plan that intersection grades of 3% or less as shown on the plan have been approved by the Knox county Dept. of Engineering and Public Works
12. Creating a pavement taper along the frontage of lot 126 to align with the pavement along the Road A frontage of lot 121
13. Review and approval of the Road E eyebrow design by the Knox County Dept. of Engineering and Public Works.
14. Extending the boulevard section on Road A to Road B
15. Meeting all other applicable requirements of the Knox County Dept. of Engineering and Public Works.
16. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC Staff.
Disposition Summary
DENY variance 1 because the requested variance can be easily brought into conformance with the requirements

APPROVE the concept plan subject to 16 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
2. Provision of street names which are consistent with the Uniform Street Naming and Numbering System for Knox County (Ord. 91-1-102).
3. Correct the vertical curve to meet the requirements as noted in variance request #1.
4. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation (TDEC).
5. Provision of a 70' wide stream buffer along Beaver Creek (35' either side of the center of the creek)
6. Provide concrete piping under Road G to carry the Beaver Creek flow
7. Provide traffic calming as may be required by the Knox county Dept. of engineering and Public Works
8. Provide Minimum Floor Elevations (MFE) for each lot along Beaver Creek or as may be required by the Knox County Engineer
9. Provide the sidewalks as shown on the plan. All sidewalks must be a minimum of 4' wide and constructed to meet the requirements of the Americans With Disabilities Act.
10. Prior to final plat approval, the applicant shall work with Knox County Schools Administration regarding the provision of a sidewalk to connect this development with the newly constructed Gibbs Elementary School. If desired by the school system, the developer will be responsible for all costs associated with making this connection.
11. Place a note on the concept plan that intersection grades of 3% or less as shown on the plan have been approved by the Knox county Dept. of Engineering and Public Works
12. Creating a pavement taper along the frontage of lot 126 to align with the pavement along the Road A frontage of lot 121
13. Review and approval of the Road E eyebrow design by the Knox County Dept. of Engineering and Public Works.
14. Extending the boulevard section on Road A to Road B
15. Meeting all other applicable requirements of the Knox County Dept. of Engineering and Public Works.
16. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC Staff.

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Edwards Place

Michael C. Rhodes, LLC


Case History