Subdivision

Concept Plan

6-SD-08-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard
APPROVE the concept plan subject to 8 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Meeting all applicable requirements of the Knoxville Dept. of Engineering.
2. Compaction or fill areas to be done in accordance with the requirements of the Knoxville Dept. of Engineering.
3. Meeting all requirements of the approved use on review development plan.
4. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
5. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. 0-280-90).
6. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
7. Place a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour areas) on this site
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.

Applicant Request

+
Subdivision
Fox Creek Subdivision
Lots
54 (Split)
Proposed Density
1.73 du/ac
Residential?
Yes - SF

Variances

1. Road grade variance from 12% to 14% between sta 2+50 and 5+30 of Blowing Rock Ln.
2. Road grade variance from 12% to 13% between sta 1+63 and 2+50 of Mist Mountain Rd.
3. Vertical curve variance from 137.5' to 90' at sta 27+41 of Fox Cove Rd.


Property Information

+
Location
West side of Fox Rd., south of Pipkin Ln.

Council District 2


Size
31.70 acres

Sector
South County

Currently on the Property
Vacant land

Growth Plan
Urban Growth Area (Outside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variances 1-3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 8 conditions

1. Meeting all applicable requirements of the Knoxville Dept. of Engineering.
2. Compaction or fill areas to be done in accordance with the requirements of the Knoxville Dept. of Engineering.
3. Meeting all requirements of the approved use on review development plan.
4. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
5. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. 0-280-90).
6. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
7. Place a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour areas) on this site
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.
Disposition Summary
APPROVE variances 1-3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard
APPROVE the concept plan subject to 8 conditions

Details of Action
1. Meeting all applicable requirements of the Knoxville Dept. of Engineering.
2. Compaction or fill areas to be done in accordance with the requirements of the Knoxville Dept. of Engineering.
3. Meeting all requirements of the approved use on review development plan.
4. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
5. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. 0-280-90).
6. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
7. Place a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour areas) on this site
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.

What's next?

+
After the Planning Commission
Because of its location in the City, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Fox Creek Subdivision

S & E Properties


Case History