Subdivision

Concept Plan

7-SA-08-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 7 conditions:


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Castle Pines, Revised
Lots
0
Proposed Density
2.12
Residential?
Yes - MF

Variances

1. Roadway grade variance from 12% to 14.74%, STA 1+35 to STA 4+35.
2. Vertical curve length variance from 318.5' to 200', at STA 1+35 (Castle Pines Ln.)
3. Horizontal curve length variance from 250' to 100', STA 0+03 to STA 0+89 (Castle Pines Ln.)
4. Horizontal curve length variance from 250' to 225', STA 2+27 to STA 6+06 (Castle Pines Ln.)
5. Horizontal curve length variance from 250' to 150', STA 7+50 to STA 9+35 (Castle Pines Ln.)
6. Intersection spacing variance on Maloney Rd. between Castle Pines Ln. and Belt Rd. from 300' to 217'.


Property Information

+
Location
Northwest side of Maloney Rd., southwest side of Belt Rd.

Commission District 9
Census Tract 35


Size
1.95 acres

Sector
South County

Currently on the Property
Residences

Growth Plan
Urban Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 7 conditions:

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
4. Certification on the final plat by the applicant's surveyor that there is at least 300 feet of sight distance in both directions along Maloney Rd. at the subdivision entrance.
5. Prior to or concurrent with recording of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the common area and drainage system.
6. Grading the bank along the proposed entrance per Knox County Department of Engineering and Public Works.
7. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 - 6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 7 conditions:

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Castle Pines, Revised

J.K. Rymer Homes


Case History