Subdivision

Concept Plan

9-SC-04-C

Recommended for approval
by the Planning Commission

APPROVE variance 1 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.

APPROVE the concept plan subject to 9 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
3. Providing a minimum right-of-way dedication of 30' for the centerline of Jenkins Rd. and Joe Hilton Rd.
4. Meeting all requirements of the approved Use-on-Review development plan.
5. Place a note on the final plat that all lots will have access from the internal road system only.
6. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County, Ord. (91-1-102)
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
8. Replacing the pipe under Jenkins Rd. per the requirements of the Knox County Dept. of Engineering and Public Works prior to the issuance of any building permits in this project.
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Jenkins Creek
Lots
34 (Split)
Proposed Density
2.63 du/ac

Variances

1. Intersection grade variance on road G at Road A from 1% to 3%.


Property Information

+
Location
West side of Joe Hinton Rd., south side of Jenkins Rd.

Commission District 5


Size
13.34 acres

Sector
Northwest County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variance 1 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.

APPROVE the concept plan subject to 9 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
3. Providing a minimum right-of-way dedication of 30' for the centerline of Jenkins Rd. and Joe Hilton Rd.
4. Meeting all requirements of the approved Use-on-Review development plan.
5. Place a note on the final plat that all lots will have access from the internal road system only.
6. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County, Ord. (91-1-102)
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
8. Replacing the pipe under Jenkins Rd. per the requirements of the Knox County Dept. of Engineering and Public Works prior to the issuance of any building permits in this project.
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variance 1 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.

APPROVE the concept plan subject to 9 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
3. Providing a minimum right-of-way dedication of 30' for the centerline of Jenkins Rd. and Joe Hilton Rd.
4. Meeting all requirements of the approved Use-on-Review development plan.
5. Place a note on the final plat that all lots will have access from the internal road system only.
6. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County, Ord. (91-1-102)
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
8. Replacing the pipe under Jenkins Rd. per the requirements of the Knox County Dept. of Engineering and Public Works prior to the issuance of any building permits in this project.
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Jenkins Creek

S & E Properties


Case History